SKU: 7225.0025
Inline Duct Fan 1100M3
- Item no.
- 7225.0025
There are 42 products.
Fans are essential in kitchens, takeaways, bakeries and canteens wherever heat, steam, odours and grease need to be extracted reliably. At iGastroNomic you will find commercial kitchen fans in a wide range, from in-line duct fans for pipe installation to matching speed controllers. Trade customers buy at B2B net prices and receive personal advice.
Fans are used wherever air needs to be moved in a targeted way: for kitchen ventilation above cooking stations, for extracting air from dishwashing areas, in storage and ancillary rooms, and in dining areas with insufficient natural ventilation. Caterers and mobile food stands rely on compact solutions because space is limited.
The right choice depends on the installation situation and the airflow path. Typical variants in our range:
The key factors are the airflow in relation to the room size and the back pressure of the ductwork. A fan that is undersized works inefficiently and fails to achieve the required air change rate. Also check the installation location: humid and grease-laden exhaust air requires units suitable for continuous operation. For speed controllers, the phase type of the system is decisive. Checking the electrical plan before purchase prevents malfunctions and unnecessary strain on the motor.
Grease and dust build up on the impeller and housing. This reduces airflow, increases noise and puts strain on the motor. Disconnect the unit from the power supply before every cleaning and observe the following points:
iGastroNomic is both manufacturer and wholesaler, with its head office in Nackenheim, Germany. You benefit from B2B net prices for trade customers, a wide selection of fans and controllers, and personal advice by phone and WhatsApp. We deliver throughout Europe. If you have questions about the correct sizing or the phase type of your system, our team will assist you directly so you can purchase fans with the right fit and confidence.
For kitchen extraction, choose units designed for grease-laden, humid air and continuous operation. The airflow should match the kitchen size and the duct length. If you have questions about sizing, the iGastroNomic team will advise you personally.
A speed controller must match the power supply type of the system. Single-phase controllers are intended for alternating current connections with one phase, three-phase controllers for three-phase connections. Check the connection in the electrical plan before purchase or ask a qualified electrician.
In-line duct fans are installed in ventilation ducts and exhaust pipes and convey air outwards through the duct run. They save space and are particularly suitable for kitchens where the fan should not be visibly mounted. Double-walled versions are also available.
Cleaning intervals depend on the grease load and operating hours. In heavily used kitchens, regular cleaning of the impeller, housing and filters is necessary to maintain performance and service life. Disconnect the unit from the power supply before every cleaning.
Yes, iGastroNomic supplies trade customers at B2B net prices and delivers throughout Europe. You can reach our personal advice team by phone or WhatsApp. This allows you to clarify questions about selection and the right model before placing your order.
Catering fans are extract and supply air units that remove steam, grease, heat and odours from kitchens and commercial premises. They are designed for restaurants, hotels, snack bars, canteens and large kitchens. When buying, the key factors are design type, airflow capacity, rotational speed and the correct connection to the ventilation system.
Every professional kitchen produces large amounts of heat, steam and grease vapour. A kitchen extract fan ensures this load is reliably removed and work areas remain usable. Also behind extractor hoods, in ductwork and in plant rooms, commercial fans handle the air transport. If you are completing your catering equipment or planning a new kitchen, you will find the right units here.
Our range includes three common designs. Radial fans with double-inlet impeller move large air volumes and overcome the resistance of grease filters and duct networks well. They are available in several sizes, from small impellers for snack bar kitchens to large units for big commercial kitchens. Box-type fans (can design) combine impeller and motor in one closed unit and are easier to integrate into hood systems or ceiling ventilation. The duct fan is fitted directly into the air duct and is suitable for installation in pipework.
| Design type | Typical use | Feature |
|---|---|---|
| Radial fan (double-inlet) | Kitchen extraction behind extractor hoods | high airflow, several sizes |
| Box-type fan (can design) | Hood systems, ceiling ventilation, large kitchens | closed unit of impeller and motor |
| Duct fan | Installation in round air ducts | compact, mounted directly in the duct |
| Higher-speed version | short ducts, high air demand | more airflow at the same size |
| Lower-speed version | noise-sensitive areas | quieter operation, lower speed |
The most important criterion is the airflow capacity in m³ per hour. It depends on kitchen size, number of cooking points and length of the ductwork. A duct fan with a capacity of around 1100 m³ per hour covers smaller applications. For hood systems, larger radial fans are the right choice. The rotational speed affects airflow and noise level: higher-speed versions deliver more air, lower-speed versions run more quietly.
Also check the mains connection and motor data as stated in the data sheet, the connection cross-section of duct or hood, and the installation position. The pressure loss caused by grease filters, bends and long duct runs is also important, as it reduces the actual airflow. When in doubt, it is worth having the sizing checked by a ventilation contractor. If you order your catering supplies together, you can plan fan, hoods and accessories in one go.
In kitchens, the fan is exposed to grease, moisture and heat. Robust housings made of galvanised steel or stainless steel, along with balanced impellers that run quietly over the long term, are therefore important. Grease deposits on the impeller cause imbalance, more noise and higher wear. They also increase the fire risk. Make sure fan, grease filter and duct routing match and that exhaust air is discharged hygienically.
Regular cleaning considerably extends service life. Switch the unit off at the mains before any work, remove grease residue from impeller and housing with a suitable degreaser, and check the bearings for noise. At the same time, grease filters and extract ducts should be cleaned at fixed intervals. If the fan runs unevenly or vibrates, dirt on the impeller is usually the cause. Replacing a replacement fan is often simple thanks to standardised sizes.
iGastroNomic reliably delivers catering and commercial fans throughout Germany, Austria, Switzerland and Europe. Whether a hotel on the coast, a snack bar in the city or a canteen in an industrial estate: the units are securely packed and dispatched quickly so your ventilation is back up and running without delay. If you have questions about size, airflow or connection, our team is happy to help you choose.
↻